Configure the Central Processing Unit (CPU) utilization and device memory threshold values to control the concurrent automation deployment on user devices based on resource utilization.

Prerequisites

Note: Option to configure threshold settings might not be available currently for Automation 360 Cloud users.

Ensure that you are logged in to the Control Room as the administrator.

Based on the CPU utilization and device memory threshold values, you can determine whether to deploy automations on user devices. If the threshold value is the same or more than the value provided, automations are not deployed on user devices.

The default values for CPU utilization and device memory are based on the following parameters:

  • When the frequency of data collection is 10 seconds, the system collects 6 data points in 1 minute.
  • When time interval to upload data is 120 seconds, the system uploads 6 data points to the Control Room every 2 minutes.
  • When the moving average time window is 2 minutes, the system uses the last 12 data points to calculate the average resource utilization.

Procedure

  1. Navigate to Administration > Settings > Devices.
  2. Edit Threshold settings for multi-user devices.
  3. Optimize the behavior for concurrent sessions by choosing one of the following options:
    • Do not enable threshold settings

      Use this option to deploy automations on single-user devices.

    • Enable threshold settings to set the maximum values:
      1. Enter the CPU and memory utilization frequency of data collection.
      2. Enter the time interval to upload data.
      3. Enter the moving average time window.
      4. Enter the CPU threshold limit for new automation deployments on a device.
      5. Enter the memory threshold limit for new automation deployments on a device.

      Use this option to deploy on multi-user devices.

    You can either enter the values or click the + (plus) sign to increase or - (minus) sign to decrease the limit.
  4. Save the settings.