Sequence to stop and start Control Room services
- Zuletzt aktualisiert2020/03/23
Sequence to stop and start Control Room services
To restart the Control Room services, you must stop and start the services in a specific sequence.
When to stop and start the Control Room services
Stop and start the Automation Anywhere Control Room services in the following scenarios:
- When you are restarting the services manually during a maintenance window.
- When you are adding nodes to a cluster. Recommendation: Skip the License service when adding nodes to a cluster.
- If the service startup mode is set as manual, then after every machine or instance restart.
- When you are updating properties in the property file, which requires a services restart.
Stopping the services on the Control Room
Stop the following Control Room services in the listed sequence:
- Automation Anywhere Control Room Caching
- Automation Anywhere Control Room Reverse Proxy
- Automation Anywhere Control Room Messaging
- Automation Anywhere Control Room Service
- Automation Anywhere Licensing
- Automation Anywhere Elastic Search Service
-
Automation Anywhere Bot Insight Service Discovery
Note: Stop the Automation Anywhere Bot Insight Service Discovery if the Bot Insight services are up and running.
Starting the services on the Control Room
Start the following Control Room services in the listed sequence.
- Automation Anywhere Licensing
- Automation Anywhere Elastic Search Service
- Automation Anywhere Control Room Reverse Proxy
- Automation Anywhere Control Room Caching
- Automation Anywhere Control Room Messaging
- Automation Anywhere Control Room Service
-
Automation Anywhere Bot Insight Service
Note: Wait for an interval of 30 seconds before starting the next service.