Silent installation error log file
- Última actualización2020/03/20
Silent installation error log file
Overview of the logs generated when you encounter an error and are not able to proceed further with silent installation.
The log file setup.log is generated during Enterprise Client or Control Room silent installation.
Working with the setup.log file
The setup.log file is created in the same directory as the response file. The /f2 option enables you to specify an alternative log file location and filename. For example: C:\Setup.exe /s /f2 C:\Setup.log
The result codes and descriptions are listed in the following table:
Result code | Description |
---|---|
0 | Success |
-1 | General Error |
-2 | Invalid Mode |
-3 | Required data not found in the setup.iss file |
-4 | Not enough memory available |
-5 | File does not exist |
-6 | Cannot write to response file |
-7 | Unable to write to the log file |
-8 | Invalid path to the InstallShield Silent response (.iss) file |
-9 | Not a valid list type (string or number) |
-10 | Data type is invalid |
-11 | Unknown error during setup |
-12 | Dialog boxes are out of order |
-51 | Cannot create the specified folder |
-52 | Cannot access the specified file or folder |
-53 | Invalid option selected |
Working with the productname.txt file
- The required Microsoft .NET Framework is not present to install the Microsoft .NET Framework.
- Services are unable to start.
For further details on installation and uninstallation of the Control Room and Enterprise Client, contact support.automationanywhere.com.